Analisa Kestabilan Transien Pada Jaringan Listrik 150KV Di Gardu Induk Waru

Authors

  • Aswin Dwi Rochman UNIVERSITAS 17 AGUSTUS 1945 SURABAYA
  • Gatut Budiono UNIVERSITAS 17 AGUSTUS 1945 SURABAYA
  • Reza Sarwo Widagdo UNIVERSITAS 17 AGUSTUS 1945 SURABAYA

DOI:

https://doi.org/10.59061/jentik.v1i3.353

Keywords:

Transient Interference, Bus Frequency Stability, Etap Software 19.0.1.y

Abstract

The occurrence of transient disturbances in the power network can be influenced by several factors, including when a short circuit occurs, motor starting, natural factors and sudden addition of load, which causes frequency instability on the bus. As in this study, an additional load of 10%, 20% and 30% for each feeder can cause transient disturbances which cause frequency stability on the 150kV bus. Frequency experiences instability when there is a transient disturbance caused by an additional load. By simulating using the Etap software, each feeder is given an additional load of 10%, showing a normal state. The 50Hz frequency experiences instability down to 47Hz and stabilizes again at 230 seconds. Hz and rose again at 245 seconds, and when given an additional load of 30% the frequency which was originally 50% experienced instability down to 47.5Hz and stabilized again at 230 seconds.

References

B. M. Tama dan S. I. Haryudo, “ANALISIS ARUS TRANSIEN TRANSFORMATOR SAAT PENYAMBUNGAN BEBAN DI BATU NIGHT SPECTACULER (BNS),” J. Tek. Elektro, vol. 09, 2020.

S. O. Ferdiansyah dan S. Sarwito, “Analisis Kestabilan Transien pada Container Crane dengan Suplai Energi Terbarukan Berbasis Simulasi,” J. Tek. ITS, vol. 9, no. 2, hlm. G131–G136, Feb 2021, doi: 10.12962/j23373539.v9i2.57096.

B. A. Arzandhy, M. Pujiantara, dan D. Fahmi, “Analisis Kestabilan Transien Dan Mekanisme Pelepasan Beban Di PT. Pusri Akibat Penambahan Generator Dan Penambahan Beban,” J. Tek. ITS, vol. 6, no. 1, hlm. 170–175, Mar 2017, doi: 10.12962/j23373539.v6i1.21145.

D. N. K. Hardani, A. A. Triyanda, dan W. Winarso, “Monitoring Stabilitas Transien Pada Sistem Tenaga Listrik,” JRST J. Ris. Sains Dan Teknol., vol. 3, no. 2, hlm. 69, Sep 2019, doi: 10.30595/jrst.v3i2.4686.

D. T. Kumara, O. Penangsang, dan N. K. Aryani, “Analisa Stabilitas Transien Pada Sistem Transmisi Sumatera Utara 150 kV - 275 kV dengan Penambahan PLTA Batang Toru 4 x 125 MW,” J. Tek. ITS, vol. 5, no. 2, hlm. B202–B206, Sep 2016, doi: 10.12962/j23373539.v5i2.16119.

R. P. Suteja, H. Suyono, dan R. N. Hasanah, “Analisis Stabilitas Transien pada Onshore Windfarm Terhubung VSC-HVDC Sistem Jawa Bali,” ELKOMIKA J. Tek. Energi Elektr. Tek. Telekomun. Tek. Elektron., vol. 10, no. 4, hlm. 873, Okt 2022, doi: 10.26760/elkomika.v10i4.873.

A. Priyadi, A. Riambodo, T. Puspita Sari, dan S. Soedibyo, “Pengaruh Penambahan SCES Terhadap Peningkatan Kestabilan Transien Menggunakan Metode Critical Trajectory Berbasis Losing Synchronism,” J. FORTECH, vol. 1, no. 1, hlm. 7–12, Feb 2020, doi: 10.32492/fortech.v1i1.216.

J. A. Pongtiku, M. Tuegeh, dan I. H. Tumaliang, “Analisa Stabilitas Transien

Downloads

Published

2023-08-02

How to Cite

Aswin Dwi Rochman, Gatut Budiono, & Reza Sarwo Widagdo. (2023). Analisa Kestabilan Transien Pada Jaringan Listrik 150KV Di Gardu Induk Waru. Jurnal Elektronika Dan Teknik Informatika Terapan ( JENTIK ), 1(3), 54–64. https://doi.org/10.59061/jentik.v1i3.353

Similar Articles

1 2 > >> 

You may also start an advanced similarity search for this article.